Greenguard type vi 40 psi insulation board is designed for use in high load applications requiring compressive strength up to 40 psi.
Minimum required psi foam board for roof.
These values are in reference to mechanically attached insulation cover boards under.
After the roof deck is prepared the rigid foam boards need to be cut to size to fit snugly together on your roof.
Meets the requirements of astm c 1325.
Rigid foam boards and are made.
P 8000 pounds h 6 inches f c 2 500 psi e 57 000 2 500 2 850 000 psi u 0 15 k 360 psi for 1 inch eps.
In fact the 20 2 psi value is beyond the elastic range of the eps material and long term creep effects must be taken into account when using that design approach.
Minimum slope of per foot as required by the international building code ibc toward roof.
Plus it s light weight easy to handle and easy to cut with a knife.
The minimum fastener pullout resistances for specific system the information listed in the chart below is for use with the referenced roof deck fastener type minimum pullout values and required penetration depths based on fasteners type.
Attach to deck board.
Composed of a lightweight cementicious core to provide exceptional impact resistance.
Extruded polystyrene closed cell foam astm c578 type iv 25 psi minimum shipped in poly wrapped units with individually wrapped or banded bundles.
The minimum insulation requirements for ceilings walls floors and foundations in new homes as listed in the 2009 2012 2015 and 2018 iecc and irc can be found in this table additional code requirements are listed on the compliance tab of this guide.
The panels need to fit together tightly to help prevent warm air from leaving the top of the building.
Rigid foam is produced in various size panels 4 ft x 8 ft 4ft x 4ft etc.
Eps foam insulation may experience dimensional and property changes when it is exposed to temperatures greater than 167 f.
The existing standard of 4 percent which would allow a 96 inch board to expand contract 3 13 16inches.
With an r value of 5 0 per inch of thickness the board increases the energy efficiency of your structures.
Ul certified for canada insulated roof deck assemblies construction no.
Meet can ulc s126 can ulc s101 and can ulc s107.
K 360 psi 2 inches 180 pci.
Insulation requirements by climate zone.
In roofing type i eps material provides the dimensional stability and compressive strength necessary to withstand light roof traffic and equipment weight at reasonably high surface temperatures.
Astm c1289 type ii class 2 grade 2 20 psi or grade 3 25 psi can ulc s704 type 2 class 3 or type 3 class 3.