Where the roof sheathing is less than 3 4 inch 19 1 mm thick the nails.
Minimum roof insulation thickness ibc.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Aluminum zinc alloy coated steel.
Or component performance alternative of section c402 1 5 roof solar reflectance and thermal emittance fenestration in building envelope.
If your community receives a lot of snow during the winter local building codes may require a minimum roof pitch for snow load which ensures that heavy snows will slide off.
Specific insulation requirements of section c402 2 thermal requirements of either.
Cap flashing shall be corrosion resistant metal of minimum nominal 0 019 inch 0 5 mm thickness.
Astm b370 minimum 16 oz sq.
Continuous insulation zones ashrae 90 1 ashrae 189 1 igcc ibc iecc 2004 2007 2010 2013 2016 2009 2011 2014 2012 2015 2009 2012 2015 0 25 1 15 20 2 15 20 25 3 15 20 25 4 15 20 302535 5 15 20 302535 6 15 20 3035 7 15 20 3540 25 8 20 3540 25 minimum r value non residential above roof deck.
Base flashing shall be of either corrosion resistant metal of minimum nominal 0 019 inch 0 5 mm thickness or mineral surfaced roll roofing weighing not less than 77 pounds per 100 square feet 4 kg m 2.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
If structural sheathing covers 40 or less of the exterior continuous insulation r value shall be permitted to be reduced by no more than r 3 in the locations where structural sheathing is used to maintain a consistent total sheathing thickness.
High yield copper for metal sheet roof covering systems.
For pre formed metal shingle systems.
The pitch of your roof is generally determined by the span of the sidewalls and the desired roof height.
In some regions however local weather may dictate roof pitch.
Both codes provide specific instructions for re roofing projects and both are clear that replacements must comply with insulation r value requirements if the roof system is part of the building thermal envelope and contains insulation entirely above the deck.
Astm a792 az 50.
R value based method of section c402 1 3 u c and f factor based method of section c402 1 4.
Base flashing shall be of either corrosion resistant metal of minimum nominal 0 019 inch 0 483 mm thickness or mineral surfaced roll roofing weighing not less than 77 pounds per 100 square feet 3 76 kg m 2.