This warranty applies to low slope roofs that use the outer perimeter instead of a drain to evacuate water.
Minimum slope for single ply membrane roofing.
Single ply membrane has a weft insertion anti wicking scrim with a density of 18 by 14 threads per inch among the highest in the industry.
The resisto single ply roofing system is guaranteed for 15 years against any manufacturing defect that may cause leaks.
Short for thermoplastic polyolefin tpo is a single ply roofing membrane that offers excellent performance at a cost effective price.
A minimum slope of 0 25 inches per foot 2 percent is recommended for all low slope roofing systems for adhered systems the substrate must be one that is approved by the system supplier.
Sprayed polyurethane foam roofing.
The idea is to provide positive drainage toward roof drains so there is no ponding water 48 hours after a rain storm.
Tpo s long term heat uv and natural fungal resistance plus flexibility without need for plasticizers also make tpo a reliable low slope roofing system.
Thermoplastic single ply membrane roofs must have a design roof slope of 1 4 12 or greater 2 slope.
These membranes are particularly effective for roofs with a very low slope between 1 8 12 1 and 4 12 33.
Table 1 01 1 chart of roofing system applicability thermoplastic single ply membranes back nailing table 1 03 1 back nailing requirement for sloped roofs table 1 04 1 the minimum fastener pullout resistances for specific systems.
For example the international building code 2018 edition ibc 2018 prescribes a 1 4 12 minimum roof slope for asphalt built up polymer modified bitumen thermoset and thermoplastic single ply and liquid applied membranes in new construction.
Roofing membranes that are single ply such as a pvc tpo or epdm requires a thin layer of a compatible single ply adhesive to be used as a primer for roofslope.
Thermoplastic single ply roofing minimum roof slope roof pitch r905 13 1.
Apply a single ply adhesive that will adhere to the existing membrane as a primer thick enough to accept a full broadcast of 16 grit silica sand or granules.
The slope of the roof must not be less than 1 12 8.
Heat welded seams provide superior strength.
The use of the resisto self adhered waterproofing membrane as a first layer and the resisto granulated cap sheet high resistance hr cap sheet as a second layer is an ideal solution to ensure the waterproofing of low slope roofs.
This 1 4 12 minimum roof slope requirement also applies to spray polyurethane foam spf roof.
Higher density products provide improved impact resistance.
Astm d4637 standard specification for epdm sheet used in single ply roof membrane.